TTI Port Devices Driver Download For Windows



Tti port devices driver download for windows 7

Kepware Aliases. Kepware Aliases.

  1. Enable wireless uplink, May 05, 2014 Virtualization has been extended from wired to wireless networks. It improves efficiency and utilization and enables customized service and multi-tenancy.
  2. Download the Windows Driver Kit (WDK) and install it. Create a driver package folder on the machine that the USB device is connected to.
  3. Microsoft® ODBC Driver 13.1 for SQL Server® - Windows, Linux, & macOS. The Microsoft ODBC Driver for SQL Server provides native connectivity from Windows, Linux, & macOS to Microsoft SQL Server and Microsoft Azure SQL Database.
  • The Legacy USB Driver is used only for the black communications interface, which requires a TTS USB to Serial adapter. The blue and green communications interfaces do not use an adapter, and this driver is not required.
Drivers
NameVersionSizeDescriptionDownload
Legacy HD04 USB Driver2.12.182.0 MB

Configuring the USB Driver

NOTICE:
Always install the USB drivers prior to connecting the USB adapter to the PC for this first time. This way, when the USB adapter is first connected it will automatically be detected and will not prompt you for a driver installation disk.

The Legacy USB drivers can be downloaded by clicking the link above titled 'Legacy HD04 USB Driver.' Alternately, these are available from the FTDI website at http://www.ftdichip.com/FTDrivers.htm. Select the VCP (Virtual COM Port) driver type for downloading.

Tti Port Devices Driver Download For Windows 7

Installing the USB Driver:
After the driver has been downloaded and saved, right-click on the file and select 'Run As Administrator'. This will launch the driver installation program. Follow the on-screen instructions to complete the install.

Determining the USB COM Port Number:
It is necessary to know which COM port the driver has assigned to the USB adapter in order for the legacy MasterTune and Datamaster products to communicate. In some cases, it will be necessary to reassign the COM port to be between COM1 and COM16. The following sections show how to do this using Device Manager.

Windows XP Com Port Reassignment:
NOTICE: You must be logged in as an administrator and the USB adapter must be connected to the PC in order to perform the following configuration.

Invoking Device Manager:
To launch device manager in Windows XP, go to Start - Settings - Control Panel and click on the System icon. This will open the Systems Properties dialog. Select the Hardware tab and then click the Device Manager button.

Tip: A shortcut to access Device Manager is to open devmgmt.msc from the Start - Run dialog:

This will bring up the device manager dialog. Go to the section labeled Ports (COM & LPT) and click on the '+' symbol to view the port assignments:

In this example, there are a total of three COM ports shown, COM1, 11, and 8. The USB adapter COM port will be labled as a USB Serial Port. Make a note of the USB Serial Port COM number; you will need it when first running MasterTune or DataMaster.

Changing the COM port assignment:
In this case there are two USB serial ports, COM11 and COM8. If the COM port number is greater than COM16, it must be reassigned to a lower number. The following example shows how to reassign COM11 to a new COM port number.

To reassign the COM port number, double click on the USB Serial Port selection to be changed. This will bring up the driver configuration dialog:

Select the Port Settings tab, then click the Advanced button: This will bring up the Advanced Port Settings dialog. In this example, note COM1 through COM10 are already 'In Use' by other devices.

Download

The TTS USB port MUST be assigned between COM1 and COM16. If all these port assignments are already in use, make a new selection between COM5 and COM16. Avoid COM1 - 4 which are usually the Laptop hardware such as IR, Modem, or BlueTooth connections. - You will receive the following warning:

Click Yes to accept the new assignment. This will generally not cause any problem - however the selection can be easily changed at a later time if necessary.

Make a note of the port number you selected, and click OK to apply the changes. When you open MasterTune or DataMaster and select the serial COM port, use this port number.

Windows Vista/7/8 Com Port Reassignment:
NOTICE: You must be logged in as an administrator and the USB adapter must be connected to the PC in order to perform the following configuration.

Invoking Device Manager:
The Windows Device Manager application must be used to configure the USB serial port connection. There are two ways to invoke device manager:

TTI Port Devices Driver Download For Windows

Type devmgmt.msc into the Windows Search box:

-OR-
From the start menu, right-clicking on Computer and selecting Manage:

You will receive the message Windows needs your permission to continue. Click the Continue button Click on Device Manager in the left-hand tree:

The right hand pane will show a list of all devices.

Click on the Ports (COM & LPT) in the right hand pane. This will show a list of all the available COM ports:

Changing the COM port assignment:
In this example there is only one USB Serial Port, COM3. To change the COM port number assigned, Double click on the USB Serial Port open the driver properties dialog:

Next, click on the Port Settings tab:

Now click the Advanced button to access the advanced port settings dialog. From this dialog, select the new COM port number:

TTI Port Devices Driver Download For Windows 10

Tti port devices driver download for windows 7

Tti Port Devices Driver Download For Windows 10

Make a note of the port number you selected, and click OK to apply the changes. When you open MasterTune or DataMaster and select the serial COM port, use this port number.